Description
RF ARC - 150 Watts Radio Frequency Surgical Diathermy with full 4 MHz
Why4 MHz?
Higher the operating frequency, lesser the lateral spread and lesser rise in temperature at surgical site. This is
exactly what happens with the 4 MHz produced by the RF ARC in both bipolar and monopolar modes.
The major advantages of 4 MHz RF ARC are
- Energy is administered gently and in a highly focused fashion.
- Pressure-less incision
- Preservation of tissue tautness
- Minimal necrosis compared to conventional units
- No carbonization / charring
- Quicker wound healing due to lower temperature and lower necrosis
- No recurrent bleeding
- Excisions taken can be examined histo-pathologically
Salient features
- Full 4 MHz Output for Monopolar and Bipolar
- Two types of monopolar cut - Fine Cut and Heavy Cut
- Two types of monopolar coag - Forced Coag and Soft Coag
- Two types of bipolar coag - Macro Coag and Micro Coag
- Monopolar Outputs via handswitch Pencil / Double pedal Footswitch
- HF output power can be set digitally in small increments
- Steady HF output at set value even under line voltage fluctuating conditions
- Audio visual monitoring of patient plate circuit
- Combined or independent use of mono bipolar functions enabled
- Separate generators for monopolar and bipolar functions
- Autoclavable accessories
APPLICATIONS
- General / Open Surgery
- Neuro Surgery
- ENT Surgery
- Cosmetic Surgery
- Conization
- Discoplasty
- Tonsillectomy
- Hemorrhoids
- Wart and corn removal
Standard Accessories
- Colour coded double pedal footswitch with cable and connector.
- Silicone rubber patient plate with detachable connection cable& rubber strap with punched holes.
- Reusable Active electrode handle with set of 4 electrodes & silicone rubber insulated cable.
- Reusable insulated bipolar forceps with silicone rubber insulated cable.
- Reusable Handswitch surgical pencil with one blade electrode.
Technical Specifications
- HF Power Display: 3-digit LED display
- HF Power control: Digital control in small increments
- Rated frequency: 4 MHZ
- Design: Voltage Independent Performance
- Monopolar Fine Cut: 150 watts (variable)
- Monopolar Heavy Cut: 150 watts (variable)
- Monopolar Forced Coag: 100 watts (variable)
- Monopolar Soft Coag: 120 watts (variable)
- Bipolar Macro Coag: 120 watts (variable)
- Bipolar Micro Coag: 60 watts (variable)
Physical Dimensions
- Size: 350mm x 325mm x 135mm
- Weight: 5 Kgs
- Power consumption: 350 Watts (230V, 50Hz)
* Due to continuous improvement in design for compliance with International standards, the technical specifications are subject to alterations without notice.