Description

RF ARC - 150 Watts Radio Frequency Surgical Diathermy with full 4 MHz

Why4 MHz? Higher the operating frequency, lesser the lateral spread and lesser rise in temperature at surgical site. This is exactly what happens with the 4 MHz produced by the RF ARC in both bipolar and monopolar modes.

The major advantages of 4 MHz RF ARC are

  • Energy is administered gently and in a highly focused fashion.
  • Pressure-less incision
  • Preservation of tissue tautness
  • Minimal necrosis compared to conventional units
  • No carbonization / charring
  • Quicker wound healing due to lower temperature and lower necrosis
  • No recurrent bleeding
  • Excisions taken can be examined histo-pathologically

Salient features
  • Full 4 MHz Output for Monopolar and Bipolar
  • Two types of monopolar cut - Fine Cut and Heavy Cut
  • Two types of monopolar coag - Forced Coag and Soft Coag
  • Two types of bipolar coag - Macro Coag and Micro Coag
  • Monopolar Outputs via handswitch Pencil / Double pedal Footswitch
  • HF output power can be set digitally in small increments
  • Steady HF output at set value even under line voltage fluctuating conditions
  • Audio visual monitoring of patient plate circuit
  • Combined or independent use of mono bipolar functions enabled
  • Separate generators for monopolar and bipolar functions
  • Autoclavable accessories
APPLICATIONS
  • General / Open Surgery
  • Neuro Surgery
  • ENT Surgery
  • Cosmetic Surgery
  • Conization
  • Discoplasty
  • Tonsillectomy
  • Hemorrhoids
  • Wart and corn removal
Standard Accessories
  • Colour coded double pedal footswitch with cable and connector.
  • Silicone rubber patient plate with detachable connection cable& rubber strap with punched holes.
  • Reusable Active electrode handle with set of 4 electrodes & silicone rubber insulated cable.
  • Reusable insulated bipolar forceps with silicone rubber insulated cable.
  • Reusable Handswitch surgical pencil with one blade electrode.
Technical Specifications
  • HF Power Display: 3-digit LED display
  • HF Power control: Digital control in small increments
  • Rated frequency: 4 MHZ
  • Design: Voltage Independent Performance
  • Monopolar Fine Cut: 150 watts (variable)
  • Monopolar Heavy Cut: 150 watts (variable)
  • Monopolar Forced Coag: 100 watts (variable)
  • Monopolar Soft Coag: 120 watts (variable)
  • Bipolar Macro Coag: 120 watts (variable)
  • Bipolar Micro Coag: 60 watts (variable)
Physical Dimensions
  • Size: 350mm x 325mm x 135mm
  • Weight: 5 Kgs
  • Power consumption: 350 Watts (230V, 50Hz)

* Due to continuous improvement in design for compliance with International standards, the technical specifications are subject to alterations without notice.